Specifications: |
Metric |
English |
Unit
Dimensions |
178
x 108 x 44 mm |
7"
x 4.25" x 1.75" |
Weights: |
|
|
Display Unit (without batteries) |
300
grams |
10.6
ounces |
8 way connection cable |
100
grams |
3.5
ounces |
Connection box |
40
grams |
1.4
ounces |
Rain gauge (w/cable and screens) |
290
grams |
10.2
ounces |
Anemometer (w/cable, u-bolts, nuts) |
550
grams |
19.4
ounces |
Thermo-Hygro Sensor (w/cable) |
300
grams |
10.6
ounces |
TEMPERATURE |
|
|
Measuring
Range |
|
|
Indoor |
0°C
to 50°C |
32°F
to 122°F |
Outdoor |
-40°C
to 60°C |
-40°F
to +140°F |
Indoor
Measurement Accuracy: |
|
|
Range: 32°F to 104°F (0°C to 40°C) |
±1°C |
±2°F |
Range: 104°F to 122° F (40°C to 50°C) |
±2°C |
±4°F |
Outdoor
Measurement Accuracy: |
|
|
Range: -40°F to 1+32°F (-40°C to 0°C) |
±2°C |
±4°F |
Range: 32°F to 104° F (0°C to 40°C) |
±1°C |
±2°F |
Range: 104°F to 122° F (40°C to 50°C) |
±2°C |
±4°F |
Range: 122°F to 140° F (50°C to 60°C) |
±3°C |
±6°F |
Resolution
(Indoor and Outdoor) |
0.1°C |
0.2°F |
Sampling
Cycle (Indoor and Outdoor) |
10
seconds |
10
seconds |
RELATIVE
HUMIDITY |
Measuring
Range |
10
to 97%RH |
10
to 97%RH |
Accuracy:
(at temperature range 32°F to 104°F (0°C to 40°C)) |
Indoor Range:25 to 90% RH |
|
|
25
to 40% RH
40 to 80% RH
80 to 90% RH |
±7%
RH
±5% RH
±7% RH |
±7%
RH
±5% RH
±7% RH |
Outdoor Range:25 to 90% RH |
|
|
25
to 40% RH
40 to 80% RH
80 to 90% RH |
±8%
RH
±6% RH
±8% RH |
±8%
RH
±6% RH
±8% RH |
Resolution
(Indoor and Outdoor) |
1%RH |
1%RH |
Sampling
Cycle (Indoor and Outdoor) |
10
Seconds |
10
Seconds |
DEW
POINT TEMPERATURE |
Measuring
Range |
|
|
Indoor |
0°C
to 47°C |
F32°
to 117°F |
Outdoor |
0°C
to 56°C |
32°F
to +133°F |
Resolution
(Indoor and Outdoor) |
1°C |
2°F |
BAROMETRIC
PRESSURE/TREND |
Measuring
Range |
795
to 1050 mb |
23.48
to 31.01 inHg |
Accuracy: |
|
|
(at
temp 32°F to 122°F (0°C to 50°C) |
±7
mb |
±.21
inHg |
Resolution |
1
mb |
0.03
inHg |
WIND
SPEED |
|
|
Measuring
Range |
0
to 56 m/s |
0
to 125.3 mph |
Accuracy:
(at temp 32°F to 122°F (0°C to 50°C) |
Range: 2 to 10 m/s |
±1
m/s |
±1
m/s |
Range: 10 to 56 m/s |
±10% |
±10% |
Resolution
(typical) |
0.2
m/s |
0.4
mph |
Sampling
Cycle: |
|
|
Gust Wind Mode |
5
seconds |
Average Wind Mode |
1
minute |
WIND
DIRECTION |
|
|
Measuring
Range |
0°
to 359° (Degrees)
0° to 350° (Compass Direction) |
Digital
Measurement Accuracy |
|
Range: 0° to 340°: |
±10°
(degrees) |
Range: <340°: |
±20°
(degrees) |
Resolution |
1°
(typical) |
Graphical
Measurement Accuracy: |
|
|
Range: 0° to 347°: |
±8°
(degrees) |
Range: <0° or >347°: |
±18°
(degrees) |
Graphical
Resolution: |
10°
(degrees) |
WIND
CHILL TEMPERATURE |
Measuring
Range |
-85°C
to +60°C |
-121°C
to +140°F |
Accuracy:
(At temp -20C to 60C w/wind speed 2 to 56 m/s) |
±8°C |
±16°F |
Resolution |
1°C |
2°F |
RAINFALL |
|
|
Daily
and Cumulative Measuring Range |
0
to 9999mm |
0
to 393.7 in |
Rainfall
Rate Measuring Range |
0
to 998mm/hr |
0
to 39in/hr |
Daily
Rainfall Accuracy (at 33.8°F to 140°F) |
Range: <.6 in (15mm) |
1
mm ± 1 digit |
.04
in ± 1 digit |
Range: .6 to 394 in (15 to
9999mm) |
±
5% ± 1 digit |
±
5% ± 1 digit |
Cumulative
Rainfall Accuracy (at 33.8°F to 140°F) |
Range: <.8 in (20mm) |
1
mm ± 1 digit |
.04
in ± 1 digit |
Range: .8 to 394 in (20 to
9999mm) |
±
5% ± 1 digit |
±
5% ± 1 digit |
Rainfall
Rate Accuracy (at 33.8°F to 140°F) |
Range: <.6 in/hr (20mm/hr) |
1
mm ± 1 digit |
.04
in ± 1 digit |
Range: .6 to 39.32 in/hr (15 to
998mm/hr) |
±
7% ± 1 digit |
±
7% ± 1 digit |
Daily
and Cumulative Resolution |
1
mm |
04
in |
Rainfall
Rate Resolution |
1
mm/hr |
04
in/hr |
Daily
Rain Sampling Cycle |
|
|
Rainfall
Rate Sampling Cycle: |
Varies
based on rainfall frequency |
Cumulative
Rain Sampling Cycle: |
Varies
based on rainfall frequency |
GENERAL |
|
|
Display: |
Liquid
Crystal (LCD) |
Clock |
Time
and date display
12/24 hour display
(selectable) |
Clock
Accuracy: |
±
0.5 Seconds/Day |